Did you already try to open the project with Project Duplicator and see the results?Maybe you can take a screenshot of your project directory to show us which files are inside Is there any cahnce to make this work on aother computer? After I click on OK, project doesn't start and therefore I have no possibility to change computer name. The only difference is, the computer name is the same as in my project, so not sure what could be causing this now.Hopefully someone can point me in the correct dirrection.RegardsAlanDid have a peek here

PLucas View Public Profile Find More Posts by PLucas June 3rd, 2005, 04:50 PM #5 Pandiani Member Join Date: Apr 2005 Location: Tz Posts: 663 Thanks for reply, When I copy project from the first comp to the second (both demo version) and when try to open I project I get following message: "Configured server is not available. Has anyone an idea what is going on? I managed to get it working, though how stable it is, I don't know. https://support.industry.siemens.com/tf/WW/en/posts/cannot-open-create-wincc-project/26591?page=0&pageSize=10

Lock mechanisms in WinCC prevent projects from being opened during a long-lastingprocess.A lock mechanism takes effect each time a WinCC project is opened. what about the databases?Best regards....If there aren't any mdf/ldf files in your project directory, than you have a big problem. can you help?I'm having problem with "the configured server is not available. Maybe versions, maybe windows...?

I recall having problems like that with the previous versions of WinCC. AttachmentPMStart.zip (124 Downloads) Last edited by: Serega77 at: 3/15/2014 7:02 PM Suggestion To thank Quote Answer 3/17/2014 11:09 AM Rate (0) Healthcheck Silver Expert Joined: 12/12/2011 Last visit: 9/23/2016 Best regards, Danielle Danielle Crespo CavalcantiSimatec Tecnologia em AutomaĆ§Ć£oBelo Horizonte - MG - Brazilwww.simatec.com.br Suggestion To thank Quote Answer 7/12/2007 3:56 PM Rate (0) matholton Regular Member Joined: 3/28/2007 But they are working.

B r g d s ,S t e B oSIMATIC HMI in Online Supporthttps://support.industry.siemens.com/tf/ Suggestion To thank Quote Answer 8/8/2012 10:14 AM Rate (0) PPND Experienced Member Joined: 10/28/2009 Then copy the "Full Computer Name" . Will simple change from single user to multi user help? https://support.industry.siemens.com/tf/WW/en/posts/error-message-cannot-open-wincc-project-project-manager-for-configured-wincc-server-is-not-running-start-project-manager-for-configured-server/41861?page=0&pageSize=10 Suggestion To thank Quote Answer 4/30/2012 5:29 PM Rate (0) angutico Member Joined: 4/30/2012 Last visit: 5/3/2012 Posts: 2 Rating: (0) Hey!, I have Win CC 7.0 sp2.

Even when i creat new project Tag managment did not alowing me to add simatic S7 protocole suit. ldf.Theycan be lockedifan incorrectconclusion ofWindows." I have project which was created in Windows XP SP3 (OS) (WinCC 7.0 SP1) and now I am opening it in Windows 7, 32 Bit, Ultimate Jetzt bin ich dabei auf WinCC 7.1 hochzurüsten, hab auch alles installiert, doch wenn ich ein altes Projekt aufrufen möchte erscheint die Fehlermeldung Cannot open/ create WinCC Project-Project Manager can´t start What should I do?

Actually I have three computers on two computers is installed winCC 6.0 edition 05/03 demo version and on the third (which is at my school) is installed full licenced winCC 6.0 https://support.industry.siemens.com/tf/ww/de/posts/cannot-open-create-wincc-project-project-manager-can-t-start-basis-application-xref/33777/?page=0&pageSize=10 When chose yes project opens and I have possibility to change computer name in my project. can you help? When i try to open any project, i have the same message "Project Manager can't start basis application XREF" I use a Wincc V7.0+Sp3 on a windows 7 PC.Can someone help

The problem occurs when I copy the entire project over to our 'test' machine, I get the following error:'Cannot open WinCC project - Project Manager for configured server is not open. http://dekovsoft.com/cannot-open/cannot-open-wincc-project.html In the application of a diagnostic file. Please DON'T use it for advertising, etc. Hope this helps, Daniel Chartier dchartier View Public Profile Find More Posts by dchartier June 3rd, 2005, 12:16 PM #3 Pandiani Member Join Date: Apr 2005 Location:

Suggestion To thank Quote Answer 4/30/2012 5:35 PM Rate (0) kustomcity Advanced Member Joined: 8/5/2008 Last visit: 11/3/2016 Posts: 26 Rating: (2) Hello colleagues,Have you checked your project for The software is running on a Windows Vista business, and Windows XP 2002 Service Pack 3 alsoIf you can, Please send idea to my email: [email protected] regards,Anh vu Last edited by: for some reason some times when we didn't close the project keeping WinCC Explorer open we had problems. Check This Out It's a really dull procedure, and we put in in a little checklist for those who weren't used to WinCC...

It would then start SQL itself and work after that.I shall look at project duplicator though, thanks. I still open it by Remote Desktop but now I use the /console option to take over the server.Thanks you all for your help.Best regards, William. I resolved the isuse as follows:1) Moved the Projekt to C:\Documents and Settings\All Users\Documents\Siemens\WinCCProjects2) Recursively removed the Read Only attrubutes (at some point the project was on a CD and this

Check the computer name of the server." 2:“The ...

Each time I trie to do this, WinCCExplorer gives the following message:Cannot open WinCC project - Project Manager for configured WinCC Server is not running - Start Project Manager for configured Since i have faced the same problem with Quickheal installed on my system. Member Joined: 8/20/2010 Last visit: 2/22/2011 Posts: 2 Rating: (0) I faced with the same. I got it working, strangely, by stopping SQL Server, then opening my project.

Paul __________________ There are 10 types of people in this world.. Check the computer name of the server"I'm using wincc 6.2 and I don't know if the project was closed on the source machine before the copy... Suggestion To thank Quote Answer 5/7/2013 9:41 AM Rate (0) FINS Advanced Member Joined: 10/17/2012 Last visit: 11/2/2016 Posts: 8 Rating: (1) Hi I am having the same problem this contact form Can you help me to find out what's going on?...Best regards....

Has anyone an idea what is going on? Suggestion To thank Quote Answer 3/8/2009 11:04 AM Rate (0) JorKiL Member Joined: 3/5/2009 Last visit: 10/13/2010 Posts: 2 Rating: (0) gponteHello Danielle, I'm having the same problem as Click here now to try it. ---------->>>>>Get FREE PLC Programming Tips New Here?