Home > Cannot Open > Cannot Open Reqpro Project

Cannot Open Reqpro Project

Watson Product Search Search None of the above, continue with my search Error: Unable to connect to datasource, when opening a RequisitePro project ReqPro; Login Fails; single user mode; SQL Server; United States English English IBM® Site map IBM IBM Support Check here to start a new keyword search. Watson Product Search Search None of the above, continue with my search Our apologies... Get assistance This option lets you send an information request and tell us about a broken link. have a peek here

Resolving the problem For RequisitePro version 7.0.0.0 and 7.0.1 perform a repair of the RequisitePro installation to resolve this issue. This exclusive lock does not use the Microsoft Access lock file (.ldb). Resolving the problem To resolve this issue, the SQL Server database needs to be set to Multi user access mode: Open the SQL Enterprise Manager Right click on the database name Submit feedback to IBM Support 1-800-IBM-7378 (USA) Directory of worldwide contacts Contact Privacy Terms of use Accessibility United States English English IBM® Site map IBM IBM Support Check here to

Watson Product Search Search None of the above, continue with my search How to determine what user has a RequisitePro project opened exclusively ldb; exclusive; requisitepro; access; oracle; sql; lock; open; Historical Number 10639 Document information More support for: Rational RequisitePro General Information Software version: 7.0, 7.0.0.1, 7.0.0.2, 7.0.0.3, 7.0.0.4, 7.0.1, 7.0.1.1, 7.0.1.2, 7.0.1.3, 7.1, 2003.06.00, 2003.06.10, 2003.06.12, 2003.06.13, 2003.06.14, 2003.06.15, 2003.06.16 Submit feedback to IBM Support 1-800-IBM-7378 (USA) Directory of worldwide contacts Contact Privacy Terms of use Accessibility United States English English IBM® Site map IBM IBM Support Check here to For more information on moving RequisitePro projects, see technote 1135389: Reconfiguring RequisitePro to open a project which has moved Additional information on moving RequisitePro projects can be found in the online

Install RequisitePro and restart computer (log on as the same administrative user after the installation and launch RequisitePro). Document information More support for: Rational RequisitePro Installation Software version: 7.0, 7.0.1, 7.1 Operating system(s): Windows Reference #: 1411882 Modified date: 12 May 2011 Site availability Site assistance Contact and feedback Watson Product Search Search None of the above, continue with my search Opening a Rational RequisitePro project results in "Project cannot be opened" error cannot open project; reqpro; project; fail; another for %1 in (*.dll) do regsvr32 -s %1 If you still receive the error: Un-install RequisitePro.

In ReqPro 7.0 and higher, it is called "exclusive.~sr" Open this file with a text editor View the UID line of this file to determine the user that has the project Note: To check that the PWD field has the correct password you will need to contact IBM Rational Support to decrypt your password. Using an administrator go to Add or Remove Programs from the Control Panel. Check This Out Error code: 19

RqDatastoreServices.Application::OpenDatastore->modDatastoreUtilities::O
penDatastore_->modDatastoreUtilities::LoadDBProperties_->RqDatastoreServices.modRqDatas
toreServices::DecryptAES128Password->RqDatastoreServices.ComponentSecurity.Decrypt71"
After closing this error, a second error message is displayed:
"Exception occurred. ( HRESULT DISP_E_EXCEPTION

First, check to make sure that the user who opened the project exclusively is actually logged out of the project. These steps can also be used for RequisitePro version 7.0.0.0 and 7.0.1. APAR status Closed as Permanent restriction. Click Add, and enter the new path to the RequisitePro project's front-end file .rqs, and click on OK.

The ~sr file will exist whenever a user has the project open. see here Symptom The full error message is as follows:
This project cannot be opened.
- Unable to locate the project information file at
Cause The path to Only user accounts that are in the Windows Administrator group have Full Control rights to the file. If a user however has the project open exclusively there will be the additional line Access=Exclusive.

For version 7.0.x the default location for the bin directory is located at the follow path: C:\Program Files\Rational\RequisitePro\bin For version 7.1 the default location for the bin directory is located at navigate here Watson Product Search Search None of the above, continue with my search Cannot open a RequisitePro project - Unable to locate the project information file 1197128; Integrations; Base ClearCase and RequisitePro; Error description Users with read-only permissions to the ?path?/RequisitePro.KDB file are unable to open projects. In this cause the RequisitePro user "Bill" has the project opened exclusively.

Log onto the computer as a local administrator. Watson Product Search Search None of the above, continue with my search Cannot open Key database /RequisitePro.kdb. Fix Pack 2) IBM Rational RequisitePro 7.0.0.1 IFIX06 Subscribe You can track all active APARs for this component. Check This Out This issue can also occur when opening a project that contains invalid login information in the projects RQL file.

If the RequisitePro project has been added to ClearCase control for baselining, then the RequisitePro project's front-end file .rqs will be located in a VOB, and the path to this file Error description When ReqPro integrates with ClearCase in UCM mode, error comes u p when open the ReqPro project and document, steps to reproduce: 1 Setup an UCM snapshot view. 2 As this is a hidden file, the current folder options may need to be set to "View hidden files and folders" in order for it to be seen.

Watson Product Search Search None of the above, continue with my search Error: The database information file for the selected project cannot be found Error occurred while parsing the RQS file;

If you are unable to delete the session file, either the user who opened the project exclusively is still in the project or the session file is locked by another process. Self-help resources Locate your IBM Easy Access site Support & downloads Site availability Site assistance Contact and feedback Need support? After making this change, try opening the project again. Solution 1: If the rql file of a RequisitePro project cannot be found, resulting in an error when you try to open the project, follow these steps to try to recover

This can occur for many reasons, including the administrative process for adding the RequisitePro project to ClearCase control for baselining. Exception occurred. (HRESULT DISP_E_EXCEPTION) The database information file (.rql) for the selected project cannot be found. Local fix Problem summary Users with read-only permissions (normally non admin users to the RequisitePro.kdb file are unable to open RequisitePro projects. this contact form Suggested actions If you typed the address, please make sure that the spelling is correct.Note: Most addresses are case sensitive.

Error occurred while parsing the RQS file. Historical Number 171536343 Document information More support for: Rational RequisitePro Database: SQL Server Software version: 7.0, 7.0.0.1, 2002.05.20, 2003.06.00, 2003.06.01, 2003.06.10, 2003.06.12, 2003.06.13, 2003.06.14, 2003.06.15, 2003.06.16 Operating system(s): Windows Reference #: APAR status Closed as program error. For information on IBM offerings, start from the IBM homepage.

All existing RequisitePro clients using this RequisitePro project will need to perform the above steps to re-connect to it. Workaround: Create a new group and add the RequisitePro user. Historical Number 184129355 Document information More support for: Rational RequisitePro General Information Software version: 7.0, 7.0.0.1, 7.0.0.2, 7.0.0.3, 7.0.0.4, 7.0.0.5, 7.0.0.6, 7.0.0.7, 7.0.0.8, 7.0.0.9, 7.0.1, 7.0.1.1, 7.0.1.2, 7.0.1.3, 7.0.1.4, 7.0.1.5, 7.0.1.6, After the repair has completed, restart and launch RequisitePro again.

Temporary fix Comments APAR Information APAR numberPK78292 Reported component nameREQUISITEPRO WI Reported component ID5724G3900 Reported release710 StatusCLOSED PRS PENoPE HIPERNoHIPER Special AttentionNoSpecatt Submitted date2009-01-08 Closed date2009-04-03 Last modified date2009-04-03 APAR is